FHD 1U 19‘ MPO-LC 96F Integrated Patch Panel
High-Density Fiber Distribution Chassis with 12 × 8F MPO&MTP(M)-LC fanout 0.9mm cables
Share to:
Description
1. Product Overview
The FHD MPO&MTP-LC integrated Patch panel is a 1U (44.45 mm) high-density fiber distribution patch panel designed for 19-inch (482.5 mm) rack mounting. It provides a fixed MPO&MTP-to-LC breakout function with a total capacity of 96 fibers:
- Rear — 8 x MPO&MTP-12 adapters accept high-density MPO&MTP trunk cables (8 x 12 fibers = 96 fibers);
- Front — 12 groups of LC ports, 8 LC ports per group (48 x LC duplex adapters = 96 LC ports);
Internal interconnection — factory-terminated 0.9 mm loose-buffered breakout cords with MPO&MTP (male) plugs, converting each MPO&MTP trunk into individual LC connections without any field splicing.
The patch panel is manufactured from aluminum alloy, combining light weight with high mechanical strength and reliable grounding. The panel supports OS1, OS2, OM3, OM4 and OM5 fiber classes, with UPC or APC polish options, making it suitable for single-mode and multimode networks from enterprise LAN to data center backbones.
2. Port Map & Capacity
Table 1 summarizes the port configuration and key parameters of the panel.

| Item | Configuration |
| Rack height | 1U (44.2 mm) |
| Chassis width | 482.5 mm (19 inch) |
| Chassis depth | 250.4mm |
| Front ports | 12 groups x 8 LC ports (48 x LC duplex, 96 LC ports) |
| Rear ports | 8 x MPO&MTP-12 adapters (96 fibers) |
| Total fiber count | 96 |
| Breakout media | MPO&MTP (male) — LC 8-core breakout cords, 0.9 mm Loose-buffered fiber |
| Fiber classes | OS1 / OS2 / OM3 / OM4 / OM5 |
| Chassis material | Aluminum alloy |
Table 1 — Port map and key parameters
3. Product Structure

| CoMPO&MTPnent | Description |
| Chassis body | Aluminum alloy frame, 1U, 482.6 mm (19-inch) rack width, with front LC panel and rear MPO&MTP plate. |
| Mounting ears | Rack-mount flanges with slotted holes, compliant with EIA-310-E rack-hole spacing. |
| Front LC panel | 12 groups of LC duplex adapters (4 duplex per group), numbered for identification. |
| Rear MPO&MTP plate | 8 x MPO&MTP-12 adapters (UPC/APC) for MPO&MTP trunk cable termination. |
| Breakout harness | Factory-terminated 0.9 mm loose-buffered breakout cords with MPO&MTP (male) plugs on one end. |
| Grounding point | Dedicated grounding stud for chassis earthing. |
| Cable management | Rear trunk-cable retention and front patch-cord guides with bend-radius protection. |
4. Other accessories
| MPO&MTP Adapter | Keyway | Footprint | Insertion Loss | Color |
![]() |
Opposed (Up-Down) Aligned (Up-Up) |
MPO&MTP/MTP standard | ≤0.2dB | Black |
| LC Quad Reduced flange Adapter | Keyway | Footprint | Insertion Loss | Color |
![]() |
Aligned (Up-Up)
|
SC Footprint | ≤0.2dB | SM:BLUE
OM3:AQUA OM4:MAGENTA OM5:LIME GREEN |
| 8F MPO&MTP-LC 0.9mm fanout 50cm | End A | End B | Optical Performance |
![]() |
1x8F MPO&MTP&MTP(Male) with Pin | 8x LC simplex 0.9 connectors | Standard MPO&MTP IL<0.5dB
Super low loss MPO&MTP IL<0.35dB LC ‘s IL<0.3dB
|
5. Design Principles
5.1 Fixed High-Density Breakout
The panel terminates 96 fibers in a single 1U of rack space: 8 MPO&MTP-12 trunk interfaces on the rear are broken out into 96 individual LC connections on the front. This removes the need for separate LC patch panels and trunk fan-out cassettes, saving rack height and cabling volume.
5.2 Factory-Terminated Breakout Harness
The internal interconnection is a pre-terminated, pre-tested 0.9 mm tight-buffered breakout harness with MPO&MTP (male) plugs. Because the harness is factory terminated, no splicing or field termination is required during installation, which improves link quality and shortens deployment time.
5.3 0.9 mm Tight-Buffered Fiber Design
0.9 mm tight-buffered fiber provides a compact, robust breakout medium inside the panel. The buffered construction protects the fiber from mechanical stress and simplifies routing while maintaining the required minimum bend radius.
5.4 Polarity Management
MPO&MTP-based links follow the polarity methods (Type A, Type B and Type C) defined in ANSI/TIA-568.3-D. The fixed breakout harness is manufactured with the selected polarity; trunk cables, harness and patch cords are chosen together to ensure end-to-end polarity consistency.
5.5 Aluminum Chassis and Standard Mounting
The aluminum alloy chassis offers a light weight, high rigidity and an effective grounding path, while ventilated openings allow natural airflow. The panel follows the 19-inch equipment practice (482.6 mm width, 44.45 mm per rack unit) in accordance with EIA-310-E / IEC 60297-3-100, ensuring drop-in compatibility with standard racks.
5.6 Fiber Protection and Cable Management
Rear trunk-cable retention and front patch-cord guides keep cables within their bend radius and provide strain relief, protecting the internal breakout harness against micro-bending loss and accidental damage.
6. International Standards & Compliance
The product is designed and tested in accordance with the following international standards:
| Standard | Title / Scope |
| IEC 61754-7 | Fibre optic connector interfaces — Type MPO&MTP connector family (multi-fiber push-on). |
| TIA-604-5 (FOCIS 5) | Fiber optic connector intermateability standard — Type MPO&MTP. |
| ISO/IEC 11801-1 | Information technology — Generic cabling for customer premises. |
| ANSI/TIA-568.3-D | Optical fiber cabling coMPO&MTPnents standard (including MPO&MTP polarity Methods A/B/C). |
| Telcordia GR-1209-CORE | Generic requirements for passive optical coMPO&MTPnents. |
| Telcordia GR-1221-CORE | Generic reliability assurance requirements for passive optical coMPO&MTPnents. |
| Telcordia GR-1435 | Generic requirements for multi-fiber optical connectors. |
| IEC 61300-3-4 | Basic test and measurement procedures — Attenuation (insertion loss measurement). |
| IEC 60825-1 | Safety of laser products — Part 1: Equipment classification and requirements. |
| EIA-310-E / IEC 60297-3-100 | 19-inch rack equipment practice: 482.6 mm width, 44.45 mm per rack unit. |
| RoHS 2011/65/EU | Restriction of hazardous substances. |
Table 3 — International standards and compliance
7. Technical Specifications
7.1 Optical Performance (Typical)
Values below are typical catalog figures measured under IEC 61300-3-4. Final guaranteed values are confirmed with the ordered configuration.
| Parameter | Typical Value |
| Breakout medium | 0.9 mm tight-buffered fiber, factory terminated |
| Front connector | Duplex LC, UPC or APC |
| Rear connector | MPO&MTP-12 adapters (mate with MPO&MTP male plugs, UPC or APC) |
| Insertion loss — MPO&MTP-12 (per mated pair) | ≤ 0. 5 dB max (typ. ≤ 0.35 dB) |
| Insertion loss — LC duplex (per mated pair) | ≤ 0.30 dB max (typ. ≤ 0.15 dB) |
| Return loss — MPO&MTP (SM APC / SM UPC / MM) | ≥ 60 dB / ≥ 50 dB / ≥ 20 dB |
| Return loss — LC (SM APC / SM UPC / MM) | ≥ 60 dB / ≥ 50 dB / ≥ 30 dB |
| Polarity | Type A / B / C (per TIA-568.3-D) |
| Durability | ≥ 500 mating cycles |
| Operating wavelength | 850 / 1300 nm (MM); 1310 / 1550 nm (SM) |
7.2 Environmental Specifications
| Item | Value |
| Operating temperature | -20 °C to +55 °C (typical) |
| Storage temperature | -40 °C to +70 °C (typical) |
| Relative humidity | 5 % to 95 % RH, non-condensing |
| Safety | Laser safety per IEC 60825-1 (Class 1M when terminated) |
| Compliance | RoHS 2011/65/EU; Telcordia GR-1209 / GR-1221 design practice |
Table 6 — Environmental specifications
8. Application Scenarios

Typical deployment scenarios include:
- Data centers — MDA / HDA / EDA zones: 40G, 100G or 400G MPO&MTP backbone links terminated on the rear, fanned out to duplex LC server and switch access ports.
- Enterprise and campus LAN — backbone consolidation and high-density patching in equipment rooms and telecommunications rooms.
- Telecom central offices and FTTx — high-density single-mode (OS1/OS2) fiber distribution and ODF-style termination.
- Cloud and colocation facilities — space-constrained patching where every rack unit of height is at a premium.
- Storage networks (SAN) and high-performance computing — deterministic, high-channel-count fiber management.
9. Installation & Maintenance
9.1 Installation
- Mount the panel on 19-inch rack rails using the slotted mounting ears; tighten all rack screws to prevent movement.
- Connect the chassis grounding stud to the rack earth before cabling.
- Plug MPO&MTP trunk cables into the rear MPO&MTP-12 adapters; the internal breakout harness is already factory-terminated, so no splicing is required.
- Patch the front LC ports with LC patch cords, respecting the minimum bend radius of the cables.
- Label each group and port according to the local labeling plan.
9.2 Maintenance and Safety
- Clean connector ferrules before every mating; always fit dust caps on unused adapters and connectors.
- Do not look directly into a fiber end-face or adapter while a light source is connected — laser safety per IEC 60825-1.
- Keep fibers within their bend radius at all times; avoid sharp folds and tensile loads on patch cords and trunk cables.
- Check insertion loss after re-mating; repeated contamination is the most common cause of excess loss in high-density patching.
10. Ordering Information
| Patch panel | – | MPO&MTP adapter | – | LC adapter | – | MPO&MTP/MTP Quality level | – | Fiber mode |
| FHD3F | 0-unloaded | 0-unloaded | 0-unloaded | 0– unloaded | ||||
| 1-Opposed (Up-Down) | 1-Lc Standard Quad no flange | 1-Standard loss Senko MPO&MTP Male | 1– G657A1 | |||||
| 2-Aligned (Up-Up) | 2-Super low loss Senko MPO&MTP Male | 2-G657A2/B2 | ||||||
| 3-Standard loss MTP Male- | 3-G657B3 | |||||||
| 4-Super low loss Elite MTP Male | 4-BIF OM1 | |||||||
| 5-Standard loss OMC MPO&MTP Male | 5-BIF OM2 | |||||||
| 6-Super low loss OMC MPO&MTP Male | 6-BIF OM3 | |||||||
| 7-BIF OM4 | ||||||||
| 8-BIF OM5 |
For Example:FHD3F-1-1-1-1