1. Product Overview

The UHD series is a family of high-density, modular fiber distribution patch panels designed for 19-inch (482.6 mm) rack mounting. Each panel accepts standardized 12-core MPO-LC cassette modules: a multi-fiber MPO trunk interface on the rear is fanned out internally to duplex LC interfaces on the front, providing a compact and orderly transition between high-density MPO backbone cabling and conventional LC patching.

Three rack-heights cover a full range of densities:

  • 4U panel — 12 module slots, up to 576fibers (48 × 12-core modules);

The chassis is manufactured from aluminum alloy for a light weight, high mechanical strength and good grounding performance. The series supports OS1, OS2, OM3, OM4 and OM5 fiber classes as well as UPC or APC polish options, making it suitable for single-mode and multimode networks from enterprise LAN to hyperscale data centers.

 

2. Model Range & Capacity

Table 1 lists the three standard models. Custom slot counts, fiber classes and connector polishes are available on request.

Model Rack Height Module Slots Max. Fiber Count Max. LC Duplex Ports Chassis Material
[UHD1S3-48] 4U 48 × 12-core 576 288 Aluminum alloy

 

3. Product Structure

Product Structure

Product name 4U 576F UHD MPO&MTP-LC Slide  drawer Rack mount patch panel Part No  UHD1S3-48
Enclosure Type Rack Mountable Fiber Count Max. 576Fibers
Installation Standard EIA 19″ Rack Material Aluminum alloy
Compliant TIA/EIA-568-C.3 Dimensions (WxDxH) 537mmx424.6mmx177mm

 

3.1 Representative Modules

1 x 12F MPO to 6x LC duplex Front ports Rear port Material Dimension(mm)
1 X 12f Mpo To 6x Lc Duplex 6x LC duplex

adapters HD Type

1 x MPO-12 ABS  95×124.5×12

 

1 x 12F MPO to 6x LC duplex Front ports Rear port Material Dimension(mm)
1 X 12f Mpo To 6x Lc Duplex2 6x HDLC duplex adapters with Inner dust-proof auto shutter HD Type 1 x MPO-12 ABS  95×124.5×12

 

3.2 Other accessories

MPO Adapter Keyway Footprint Insertion Loss Color
Mpo Adapter Opposed (Up-Down)
Aligned (Up-Up)
MPO/MTP standard ≤0.2dB Black

 

 LC DX Reduced flange Adapter Keyway Footprint Insertion Loss Color
Lc Dx Reduced Flange Adapter  Aligned (Up-Up)

 

SC Footprint ≤0.2dB SM:BLUE

OM3:AQUA

OM4:MAGENTA

OM5:LIME GREEN

 

4. Technical Specifications

4.1 Mechanical Specifications

Mechanical Specifications

Item 4U Model
Rack height 4U (177.8mm)
Chassis width 537.23 mm (19 inch)
Chassis depth 424.6 mm
Module slots 48
Max. fiber capacity 576
Chassis material Aluminum alloy
Mounting 19-inch rack, EIA-310-E

 

4.2 Optical Performance (12-core MPO-LC Module, Typical)

Values below are typical catalog figures measured under IEC 61300-3-4. Final guaranteed values are confirmed with the ordered configuration.

Parameter Typical Value
Front connector Duplex LC, UPC or APC
Rear connector MPO-12, UPC or APC
Insertion loss — MPO-12 ≤ 0.50 dB max (typ. ≤ 0.35 dB)
Insertion loss — LC duplex ≤ 0.30 dB max (typ. ≤ 0.15 dB)
Return loss — MPO (SM APC / SM UPC / MM) ≥ 60 dB / ≥ 50 dB / ≥ 20 dB
Return loss — LC (SM APC / SM UPC / MM) ≥ 60 dB / ≥ 50 dB / ≥ 30 dB
Polarity Type A / B / C (per TIA-568.3-D)
Durability ≥ 500 mating cycles
Operating wavelength 850 / 1300 nm (MM); 1310 / 1550 nm (SM)

 

4.3 Environmental Specifications

Item Value
Operating temperature -20 °C to +55 °C (typical)
Storage temperature -40 °C to +70 °C (typical)
Relative humidity 5 % to 95 % RH, non-condensing
Flammability / safety Laser safety per IEC 60825-1 (Class 1M when terminated)
Compliance RoHS 2011/65/EU; Telcordia GR-1209 / GR-1221 design practice

 

5. Design Principles

5.1 High-Density MPO-to-LC Transition

The panel converts dense MPO trunk cabling (12 or 24 fibers per connector) into individual duplex LC connections. Up to 144 fibers can be terminated in a single 1U of rack space, reducing rack footprint and cabling volume compared with conventional LC patch panels.

5.2 Modular and Scalable Architecture

Modules are installed into the panel only as required and can be added, replaced or reconfigured without disturbing adjacent circuits. This front-accessible, tool-less design shortens deployment time and simplifies future upgrades.

5.3 Polarity Management

MPO-based links follow the polarity methods (Type A, Type B and Type C) defined in ANSI/TIA-568.3-D. Modules, trunk cables and patch cords are selected together to maintain end-to-end polarity consistency.

5.4 Fiber Protection and Cable Management

The internal fan-out fiber is factory terminated and protected within the module. Front and rear cable-management features enforce the minimum bend radius and provide strain relief, protecting fibers against micro-bending loss and accidental damage.

5.5 Material and Thermal Design

The aluminum alloy chassis combines low weight with high rigidity and provides an effective grounding path. Ventilated front/rear openings allow natural airflow through the panel, helping to keep modules within their operating temperature range in dense racks.

5.6 Standards-Based Mechanical Design

All panels follow the 19-inch equipment practice (482.6 mm mounting width, 44.45 mm per rack unit) in accordance with EIA-310-E / IEC 60297-3-100, ensuring drop-in compatibility with standard data-center and telecom racks.

 

6. International Standards & Compliance

The product family is designed and tested in accordance with the following international standards:

Standard Title / Scope
IEC 61754-7 Fibre optic connector interfaces — Type MPO connector family (multi-fiber push-on).
TIA-604-5 (FOCIS 5) Fiber optic connector intermateability standard — Type MPO.
ISO/IEC 11801-1 Information technology — Generic cabling for customer premises (fiber classes and channel performance).
ANSI/TIA-568.3-D Optical fiber cabling components standard (including MPO polarity Methods A/B/C).
Telcordia GR-1209-CORE Generic requirements for passive optical components (optical and mechanical performance).
Telcordia GR-1221-CORE Generic reliability assurance requirements for passive optical components.
Telcordia GR-1435 Generic requirements for multi-fiber optical connectors.
IEC 61300-3-4 Basic test and measurement procedures — Attenuation (insertion loss measurement).
IEC 60825-1 Safety of laser products — Part 1: Equipment classification and requirements.
EIA-310-E / IEC 60297-3-100 19-inch rack equipment practice: 482.6 mm width, 44.45 mm per rack unit.
RoHS 2011/65/EU Restriction of hazardous substances.

 

7. Application Scenarios

Application Scenarios

Typical deployment scenarios include:

  • Data centers — MDA / HDA / EDA zones: 40G, 100G or 400G MPO backbone links terminated on the rear, fanned out to duplex LC server and switch access ports.
  • Enterprise and campus LAN — backbone consolidation and structured cabling distribution in equipment rooms and telecommunications rooms.
  • Telecom central offices and FTTx — high-density fiber distribution and ODF-style termination for single-mode (OS1/OS2) networks.
  • Cloud and colocation facilities — space-constrained high-density patching where rack height is at a premium.
  • Storage networks (SAN) and high-performance computing — deterministic, high-channel-count fiber management.

 

8. Installation & Maintenance

8.1 Installation

  • Mount the panel on 19-inch rack rails using the slotted mounting ears; tighten all rack screws to prevent movement.
  • Connect the chassis grounding stud to the rack earth before cabling.
  • Install cassette modules from the front until they click into the slot latch; fit blanking plates over unused slots.
  • Route MPO trunk cables at the rear and LC patch cords at the front, respecting the minimum bend radius of the cables.
  • Label each slot and port according to the local labeling plan.

8.2 Maintenance and Safety

  • Clean connector ferrules before every mating; always fit dust caps on unused adapters and connectors.
  • Do not look directly into a fiber end-face or adapter while a light source is connected — laser safety per IEC 60825-1.
  • Keep fibers within their bend radius at all times; avoid sharp folds and tensile loads on the fan-out tails.
  • Check insertion loss after re-mating; repeated contamination is the most common cause of excess loss in high-density patching.

 

9. Ordering Information

Unloaded patch panel

Part no. – Products Details
UHD1S1-12 1U 144F UHD MPO&MTP-LC Slide Drawer Rack mount patch panel
UHD1S2-24 2U 288F UHD MPO&MTP-LC Slide drawer Rack mount patch panel
UHD1S3-48 4U 576F UHD MPO&MTP-LC Slide drawer Rack mount patch panel

 

Full loaded MPO/MTP-LC Cassette

Cassette – Material – Adapter Type – MPO/MTP Quality level – Fiber mode
UHD1S 1-BLACK Color Cassette 1-HD type LC DX adapter +MPO(Opposed) 1-Standard loss MPO Male Senko 1– G657A1
2-Transparent Cassette 2-HD type LC DX with Inner dust-proof auto shutter adapter +MPO(Opposed) 2-Super low loss MPO Male Senko 2-G657A2/B2
3-HD type LC DX adapter +MPO(Aligned) 3-Standard loss MTP Male 3-G657B3
4-HD type LC DX with Inner dust-proof auto shutter adapter +MPO(Aligned) 4-Super low loss  Elite MTP Male 4-BIF OM1
5-Standard loss MPO Male OMC 5-BIF OM2
6-Super low loss MPO Male OMC 6-BIF OM3
7-BIF OM4
8-BIF OM5

For Example:UHD1S-1-1-1-1

Application