深圳比惠州工资高 2000 左右

The 12-fiber armored MTP-LC breakout patch cord is a ruggedized, high-density fiber optic interconnect engineered for mission-critical data center and telecommunications deployments. Featuring a 12-fiber MTP connector on one end and twelve individual LC simplex or 6x LC DX or 6x LC uniboot connectors on the breakout legs, this assembly enables reliable transitions from multi-fiber trunk infrastructure to standard single-fiber equipment interfaces, with armored cable construction ensuring superior mechanical protection.

Description

Design Principles

Armored Cable Construction. Each breakout leg integrates a helically wound stainless steel interlock armor layer, delivering crush resistance ≥440 N/10 cm, full rodent protection, and impact resistance. The armored design eliminates external conduit requirements in exposed cable pathways, reducing infrastructure cost and installation complexity in harsh or high-traffic environments.

Compact 2.0mm Profile. Each breakout leg maintains a 2.0 mm outer diameter despite integrated armor, minimizing cable bulk while preserving mechanical integrity. Tight-buffered 900 μm fibers with aramid yarn strength members ensure reliable tensile performance.

MTP Connector Technology. The MTP connector houses twelve precision-aligned optical fibers within a single-row MT ferrule, utilizing high-accuracy stainless steel guide pins for sub-micron positioning. MTP connectors feature floating ferrule design and elliptical guide pins for optimized physical contact, delivering superior multi-fiber alignment compared to standard MPO. Available in Type A, Type B, and Type C polarity configurations per TIA-568.2, supporting both 12-fiber parallel optics and fanout architectures.

Optical Performance. LC connectors are terminated with premium zirconia ceramic ferrules polished to UPC profile, achieving insertion loss ≤ 0.25 dB and return loss ≥ 50 dB. Every assembly undergoes 100% end-face interferometric inspection per IEC 61300-3-35 and IL/RL verification per IEC 61300-3-4.

Optical Specification

Spec items. Insertion loss (IEC 61300-3-xx) Return loss(IEC 61300-3-6 /TIA/EIA-455-107) Standard
MTP SM Standard MTP:≤0.75dB(max), ≤0.50dB(Typical)
Elite MTP:≤0.35dB(max), ≤0.20dB(Typical)
APC≥60dB; PC≥50dB IEC 61300-3-4 / TIA/EIA-455-34
MTP MM Standard MTP:≤0.6dB(max), ≤0.50dB(Typical)
Elite MTP:≤0.35dB(max), ≤0.20dB(Typical)
PC≥50dB IEC 61300-3-34 / TIA/EIA-455-61
LC SM ≤0.3dB APC≥60dB; PC≥50dB IEC 61300-3-4 / TIA/EIA-455-34
LC MM ≤0.3dB PC≥50dB IEC 61300-3-34 / TIA/EIA-455-61

End-Face 3D Interference Index

Parameter MTP® LC Standard
Radius of Curvature, ROC X: ≥ 2000 mm,Y: 50 mm 10 ~ 25 mm (PC)
5 ~ 12 mm (APC)
IEC 61300-3-30
Fiber Height / Protrusion -300 nm ~ +300 nm ± 100 nm IEC 61300-3-30
Apex Offset N/A ≤ 50 μm IEC 61300-3-30
Angle 8.0° ± 0.5° (APC) 8.0° ± 0.5° (APC) IEC 61300-3-30
Core Dip “-200 nm ~ +300 nm (SM)” N/A IEC 61300-3-30

End-Face LC/SC/FC/ST End-face Quality (SM)

Zone Range (μm) Scratches Defects Reference
A: Core 0 to 25 None None IEC 61300-3-35:2015
B: Cladding 25 to 115 None None
C: Adhesive 115 to 135 None None
D: Contact 135 to 250 None None
E: Rest of ferrule None None

 End-Face LC/SC/FC/ST End-face Quality (MM)

Zone Range (μm) Scratches Defects Reference
A: Core 0 to 65 None None IEC 61300-3-35:2015
B: Cladding 65 to 115 None None
C: Adhesive 115 to 135 None None
D: Contact 135 to 250 None None
E: Rest of ferrule None None

MTP® Connector Types

Connector Fiber Channel
Mtp® Jumper Cable
12f Mtp
MTP® Female no pin Connectors 12 Fibers
Note: Female connector need to connect with male connector type.

MTP® products’ Details& Standard

Connector Reference Housing Details
MTP® Singlemode IEC 61754-7 SM APC: Green connectors+black boot (Standard Loss MTP)

SM APC: Yellow connectors+black boot (Elite MTP)

MTP® Multimode IEC 61754-7 OM3 PC: Aqua connectors+black boot (Standard Loss&Elite MTP)

OM4 PC: Magenta connectors+black boot (Standard Loss&Elite MTP)

  • Meets IEC Standard IEC-61754-7; IEC61755, Telcordia GR-1435-CORE, JIS C5982; TIA-604-5(FOCIS5) compliant
  • Structured cabling per TIA-568-C
  • 10G Fiber Channel Compliant
  • 40G and 100G IEEE 802.3

Cable Parameters-12F Microfiber cable 1

12f Micro Fiber Armored Cable截面12f Micro Fiber Armored Cable 1

Item Contents Unit Data
Fiber type / / SM G652D;OM2,OM3,OM4
Cable diameter ±0.3 mm 3.0±0.2
Subunit fiber Material / PVC,LSZH(CRP certification)
Fiber count 12x250um Blue,Orange,Green,Brown,Grey,White,

Red,Black,yellow,purple,pink,aqua

Armored unit Material / SUS204 Stainless-steel Spiral Tube
Diameter mm 1.8±0.05
Strength member Material / Aramid Yarn
Outer sheath material / LSZH(CRP certification),PE,PVC,TPU,OFNP
Color / Blue,Yellow,Black, Orange,Grey,Aqua……..
Cable weight ±5% kg/km 15

Cable Parameters-12F Microfiber cable 2

12f Micro Fiber Double Sheath Armored Cable 3.0mm Od For Mpo截面 12f Micro Fiber Double Sheath Armored Cable 3.0mm Od For Mpo

Item Contents Unit Data
Fiber type / / SM G652D;OM2,OM3,OM4
Cable diameter ±0.3 mm 3.0±0.2
Subunit cable Material / PVC,LSZH(CRP certification)
Fiber count 12x250um Blue,Orange,Green,Brown,Grey,White,Red,Black, ,yellow,purple,pink,aqua,
Diameter mm 1.4
Armored unit Material / SUS204 Stainless-steel Spiral Tube
Diameter mm 2.0±0.2
Strength member Material / Aramid Yarn
Outer sheath material / LSZH(CRP certification),PE,PVC,TPU,OFNP
Color / Blue,Yellow,Black, Orange,Grey,Aqua……..
Cable weight ±5% kg/km 15

Mechanical & Environmental Performance

Item Contents Value
Max. tensile load Short term 600N fiber strain≤0.6%
Long term 300N
Max. crush resistance Short term 3000N/100mm
Long term 1500N/100mm
Min.

bending radius

Installation 40 x cable diameter
Operation 20 x cable diameter
Temperature range Operation -20℃ ~ +70℃
Installation -20℃ ~ +60℃
Storage/transportation -20℃ ~ +70℃

 Flame retardant Performance

Cable material Standard
LSZH CPR : B2ca, Cca, Dca, Eca,Fca
OFNP&OFNR UL-94V0

 Cable Jacket Material

Item OFNP Plenum LSZH OFNR Riser
Smoke emission Extremely low Very low Heavy black smoke
Toxic halogen gas None Zero High (chloride)
Fire resistance rank Highest Medium Medium-low
Plenum air space use Allowed Not UL certified, restricted Strictly prohibited
Vertical riser shaft Supported Supported Optimized for riser shafts
Rigidity & hardness Stiff, firm texture Soft, flexible Moderate flexibility
Cost Highest Mid-range Lowest

Benefits of Armored Fiber Patch Cable

Common fiber optic cable is fragile, which needs to be protected, especially when in harsh applications where cables could be compromised by rodents, constant wear and tear or weather damage. Armored fiber patch cable retains all the features of standard fiber cable but is much stronger due to its extra layers of armor. With the protection of flexible and durable steel tube, armored fiber patch cable will ensure the excellent operation of your network.

Photo5

Pre-terminated MTP Technology-Polarity 24F MTP

Cable Drawing &Polarity

Image 1

This is Staggered harness cable, Each fanout cable length is different.

Image 2

This is Straight harness cable, Each fanout cable length is same.

Length Tolerance

Overall Length(L)(m) length of tolerance(cm)
0<L<1 +5/-0
1<L<10 +10/-0
10<L<40 +15/-0
40<L +0.5% x L/-0

Applications

  • Hyperscale & Enterprise Data Centers: 100G/400G SR4 and SR4.2 parallel optics deployment, fanning out from 12-fiber MPO trunk infrastructure to individual QSFP28/QSFP-DD transceiver ports in spine-leaf architectures requiring enhanced cable protection.
  • Industrial Automation & Oil/Gas: Fiber distribution in control rooms and field cabinets where armored cables resist vibration, chemical exposure, and rodent intrusion.
  • FTTx / GPON Networks: Bridging 12-fiber distribution frames to individual subscriber ONT drops in passive optical network architectures.
  • Telecom Central Offices: High-density MPO-to-LC transitions for legacy and next-generation switching equipment in space-constrained frames.
  • Military & Tactical Communications: Field-deployable fiber links requiring ruggedized, MIL-spec cable assemblies for rapid deployment under adverse conditions.

 Summary: The 12F 2.0mm harness is specifically optimized for high-density backbone transitions and 40G/100G breakout applications, offering the physical durability required for complex data center routing while ensuring seamless speed migration.

Photo11

 

Application

Free Quote